I. Overview In the air source heat pump industry, units integrate dual-cycle refrigerant sy...
Details

I. Overview
In the air source heat pump industry, units integrate dual-cycle refrigerant systems for both heating and cooling, high-power compressors, fan assemblies, water-side heat exchange modules, and electrical control systems. The complete-unit assembly process is complex, with stringent requirements for refrigerant pipeline welding, pressure-holding leak testing, electrical wiring, and complete-unit operating tests. Under the traditional independent-workstation assembly mode, large units are difficult to handle, process flow tends to become disordered, and defective products — such as those with refrigerant leaks, wiring errors, or substandard heat exchange performance — are hard to identify early in the production stage. As the core non-standard equipment for heat pump complete-unit manufacturing, the air source heat pump assembly line (air energy production line) adopts a heavy-duty roller conveyor structure adapted to heavy air energy units, enabling continuous end-to-end operations including on-line pre-assembly, pipeline welding, vacuum evacuation and refrigerant charging, complete-unit performance testing, and final inspection off-line.
The complete air energy heat pump production line carries heat pump units on heavy-duty roller conveying. Units are placed on wooden pallets and flow along the roller line, with each workstation equipped with refrigerant recovery, vacuum evacuation, pressure-holding leak testing, and electrical inspection modules. The line is fitted with workstation industrial control terminals that bind unit SN serial numbers and collect key operating parameters — refrigerant pressure, inlet/outlet water temperature, operating current, and heating capacity — enabling full traceability of complete-unit production data. This air source heat pump production line supports mixed-line production of multiple models, including residential air energy units, commercial heating & cooling heat pumps, and low-temperature heat pumps. Line length and workstation configuration can be customized according to factory layout, unit weight, and capacity takt. It is widely used for new production line construction in air energy plants and for upgrading existing workshop lines, resolving pain points such as difficult handling of heavy heat pump units, missed refrigerant system inspection, and time-consuming complete-unit operating tests, while stabilizing shipped performance and reducing after-sales failures caused by refrigerant leaks and insufficient heating capacity.
II. Assembly Process
The air source heat pump assembly line strictly segments workstations according to heat pump unit manufacturing processes, with the heavy-duty roller line carrying units through smooth flow:
- Frame pre-assembly workstation: complete pre-assembly of the base frame, compressor, heat exchanger, and fan frame; secure core components; arrange refrigerant pipeline and water circuit interfaces; provide pipeline support and protection.
- Pipeline welding & pressure-holding leak testing workstation: perform copper pipeline welding operations and high-pressure holding tests to check whether refrigerant pipeline weld seams and joints leak; non-conforming units are locked at the workstation and prevented from flowing to the next process, avoiding refrigerant leaks after subsequent charging.
- Vacuum evacuation & refrigerant charging workstation: connect a vacuum unit for deep evacuation of the refrigerant circuit, add refrigerant in precise quantity per model, and record the charging amount parameters simultaneously.
- Complete-unit operating performance test workstation: the core workstation of this line. Connect simulated water circuits and power; the unit starts heating/cooling circulation; continuously monitor compressor current, fan operating status, inlet/outlet water temperature, and system high/low pressure; verify unit heating capacity and defrosting logic, simulating actual field operating conditions.
- Electrical safety final inspection workstation: complete insulation, grounding, and withstand voltage (hi-pot) tests; re-verify control logic; verify all operating parameters; the system determines pass or fail.
- Off-line sorting workstation: conforming products are conveyed to the packaging workstation; non-conforming products are diverted on-site for rework and re-enter performance testing after repair.
The complete process integrates heavy material conveying, refrigerant system inspection, and complete-unit operating aging tests, meeting the mandatory factory acceptance inspection requirements for refrigerant system safety and thermal performance in the heat pump industry.
III. Customizable Parameters
The air energy heat pump production line is a heavy-duty non-standard assembly and testing line; the line body, tooling, and test modules can all be customized according to customer product specifications:
- Conveying main body: standard heavy-duty roller conveyor line, with roller load capacity selected per unit weight; line length and workstation count are customized per capacity takt; straight and L-shaped layouts available; roller drive with variable frequency speed control. Chain conveying is available as an alternative for heavy-load applications.
- Carrying tooling: compatible with wooden pallets / metal tooling bases, with rapidly adjustable limit stops, accommodating residential and commercial air source heat pump units of different sizes.
- Electrical control & data system: workstation touchscreens with MES interface support, storing pressure-holding, refrigerant charging, and operating test data for each unit, with barcode traceability and audible/visual alarms for non-conforming products.
- Integrated test modules: optional refrigerant pressure-holding leak testing system, vacuum evacuation & refrigerant charging unit, water system simulation module, and safety (hi-pot) test bench; centralized arrangement of refrigerant recovery piping.
- Line structure: frames available in carbon steel powder-coated; adjustable support feet to accommodate workshop floor levels; optional protective fencing and emergency-stop safety interlock systems.
- Compatibility & expansion: reserved provision for robot welding assist workstations, automatic marking, and nameplate application workstations; adapts to changeover production of multiple product types, including low-temperature enthalpy-injection heat pumps and swimming pool heat pumps.
The air source heat pump production line is a heavy-load non-standard line, with design focus on heavy-load conveying stability, refrigerant pipeline safety control, and on-line thermal performance testing of complete units, helping heat pump manufacturers achieve scaled, standardized unit assembly and inspection.